Return to site

Hp Proliant Offline Array Configuration Utility Iso

broken image
Hp Proliant Server
Hp Smart Array Configuration Utility Download
HP ProLiant Offline Array Configuration Utility. The HP Offline Array Configuration Utility provides an ISO image that. Hard to find HP tools: The Offline Array. ACU Offline Utility disk for all HP ProLiant. SMart Array P212 HP Array Configuration Utility Software. Hp drivers that delivers on topic. 2 drivers that will not an upgrade. Customer has installed a hp proliant server dl 380 g5 for more than 9 years, it has a smart array p400 installed also for more than 9 year working every day more than 78800 hours. Smartstart does three useful things for us, setup raid with hp array configuration utility. HP ProLiant Offline Array Configuration Utility. The HP Offline Array Configuration Utility provides an ISO image that. Hard to find HP tools: The Offline Array. ACU Offline Utility disk for all HP ProLiant. Hp Proliant Server Printable version HP ProLiant Offline Array Configuration Utility
By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: Software - System Management Version: 9.10.22.0(4 Jun 2012) Operating System(s): Microsoft Windows 7 (64-bit) Microsoft Windows Server 2003 Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 R2 Foundation Edition Microsoft Windows Server 2008 W32 Microsoft Windows Server 2008 x64 Microsoft Windows Storage Server 2003 Microsoft Windows Storage Server 2003 x64 Editions Microsoft Windows Unified Data Storage Server 2003 x64 Edition Microsoft Windows Vista (32-bit) Microsoft Windows Vista (64-bit) Microsoft Windows XP Professional Microsoft Windows XP Professional x64 Edition Oracle Linux 5 (AMD64/EM64T) Oracle Linux 5 (x86) Oracle Linux 6 (AMD64/EMT64) Oracle Linux 6 (x86) Red Hat Enterprise Linux 4 (AMD64/EM64T) Red Hat Enterprise Linux 4 (x86) Red Hat Enterprise Linux 5 Desktop (x86) Red Hat Enterprise Linux 5 Desktop (x86-64) Red Hat Enterprise Linux 5 Server (x86) Red Hat Enterprise Linux 5 Server (x86-64) Red Hat Enterprise Linux 6 Server (x86) Red Hat Enterprise Linux 6 Server (x86-64) SUSE Linux Enterprise Server 10 (AMD64/EM64T) SUSE Linux Enterprise Server 10 (x86) SUSE Linux Enterprise Server 11 (AMD64/EM64T) SUSE Linux Enterprise Server 11 (x86) SUSE Linux Enterprise Server 9 (AMD64/EM64T) SUSE Linux Enterprise Server 9 (x86) Microsoft Windows 7 (32-bit) File name: hpacuoffline-9.10-22.0-x86.zip (101 MB) The HP Offline Array Configuration Utility provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows.This deliverable will allow users to boot into an environment from which they can choose various configuration utilities (ACU, HPACUCLI, and HPACUSCRIPTING) prior to the Host OS loading. Users can then configure or maintain the detected and supported devices such as HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers.You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, diagnosing and monitoring potential issues, or to reconfigure your array controller.
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.10.22.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: 475ea02382649432cd212385c6036163 hpacuoffline-9.10-22.0-x86.zip
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Download the offline ACU zip file and then burn/write the ISO image to the desired media (CD/DVD/USB Key/SD card) using the HP USB Key Utility for Windows
Insert the media into the server and boot the server. Verify that your system can boot from the desired media.
A menu with the three boot options (ACU, ACUCLI, HPACUSCRIPTING) is shown. The user can manually select which utility to start; or if no selection is made, ACU is automatically started.
This image is a bootable environment that immediately starts ACU to allow configuration of storage.
This ISO image can also be mounted as a CD image through ILO2 or higher. It is highly recommended that your server have the latest BIOS firmware and latest ILO2 or higher firmware installed.
This utility provides the following boot options:
* The web based Array Configuration Utility (ACU)
* The command line Array Configuration Utility (ACUCLI)
* The command line Array Configuration Scripting Utility (HPACUSCRIPTING)
End User License Agreements:
Hewlett-Packard End User License Agreement
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.
For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.
Version:9.40.12.0 (19 Feb 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.30.15.0 (26 Oct 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Logical Drive Movement enhancements
Version:9.20.9.0 (4 Sep 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Smart Array P721m
Version:9.10.22.0 (4 Jun 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.10.22.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.
Version:9.0.24.0 (27 Mar 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.0.24.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
The following controllers:
HP Smart Array P222
HP Smart Array P420
HP Smart Array P421
HP Smart Array P220i
HP Smart Array P420i
Added support for the following features/devices:
Smart Array Advanced Pack 2.0 (SAAP 2.0)
SAAP 2.0 provides full SAAP 1.0 feature functionality with the following additions:
RAID 1/10 Advanced Data Mirroring (ADM)
Moving and Deleting of Individual Logical Volumes
Move operation now supports SATA to SAS, SAS to SATA
Predictive Spare Activation
128 physical drives
SmartSSD Wear Gauge
Updated Cache Ratio settings
Additional Strip Sizes - 512, 1024 on supported controllers and configurations
Device Temperatures - Controllers, Capacitors, Cache Modules, and Hard Drives
Overall Performance improvements
3 TB physical drives
Version:8.75.12.0 (22 Jun 2011)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 8.75.12.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
The 8.75.12.0 versions of the utilities support:
SmartSSD Wear Gauge
This feature is accessible through the Diagnostic Tab in ACU, and the ssdinfo command in ACUCLI
Greater than 2.2 TB Hard Drives
Type: Software - System Management Version: 9.10.22.0(4 Jun 2012) Operating System(s): Microsoft Windows 7 (32-bit) Microsoft Windows 7 (64-bit) Microsoft Windows Server 2003 Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 R2 Foundation Edition Microsoft Windows Server 2008 W32 Microsoft Windows Server 2008 x64 Microsoft Windows Storage Server 2003 Microsoft Windows Storage Server 2003 x64 Editions Microsoft Windows Unified Data Storage Server 2003 x64 Edition Microsoft Windows Vista (32-bit) Microsoft Windows Vista (64-bit) Microsoft Windows XP Professional Microsoft Windows XP Professional x64 Edition Oracle Linux 5 (AMD64/EM64T) Oracle Linux 5 (x86) Oracle Linux 6 (AMD64/EMT64) Oracle Linux 6 (x86) Red Hat Enterprise Linux 4 (AMD64/EM64T) Red Hat Enterprise Linux 4 (x86) Red Hat Enterprise Linux 5 Desktop (x86) Red Hat Enterprise Linux 5 Desktop (x86-64) Red Hat Enterprise Linux 5 Server (x86) Red Hat Enterprise Linux 5 Server (x86-64) Red Hat Enterprise Linux 6 Server (x86) Red Hat Enterprise Linux 6 Server (x86-64) SUSE Linux Enterprise Server 10 (AMD64/EM64T) SUSE Linux Enterprise Server 10 (x86) SUSE Linux Enterprise Server 11 (AMD64/EM64T) SUSE Linux Enterprise Server 11 (x86) SUSE Linux Enterprise Server 9 (AMD64/EM64T) SUSE Linux Enterprise Server 9 (x86) Description The HP Offline Array Configuration Utility provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows.This deliverable will allow users to boot into an environment from which they can choose various configuration utilities (ACU, HPACUCLI, and HPACUSCRIPTING) prior to the Host OS loading. Users can then configure or maintain the detected and supported devices such as HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers.You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, diagnosing and monitoring potential issues, or to reconfigure your array controller. Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.10.22.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array. Installation Instructions
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: 475ea02382649432cd212385c6036163 hpacuoffline-9.10-22.0-x86.zip
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Download the offline ACU zip file and then burn/write the ISO image to the desired media (CD/DVD/USB Key/SD card) using the HP USB Key Utility for Windows
Insert the media into the server and boot the server. Verify that your system can boot from the desired media.
A menu with the three boot options (ACU, ACUCLI, HPACUSCRIPTING) is shown. The user can manually select which utility to start; or if no selection is made, ACU is automatically started.
This image is a bootable environment that immediately starts ACU to allow configuration of storage.
This ISO image can also be mounted as a CD image through ILO2 or higher. It is highly recommended that your server have the latest BIOS firmware and latest ILO2 or higher firmware installed.
This utility provides the following boot options:
* The web based Array Configuration Utility (ACU)
* The command line Array Configuration Utility (ACUCLI)
* The command line Array Configuration Scripting Utility (HPACUSCRIPTING) Release Notes
End User License Agreements:
Hewlett-Packard End User License Agreement
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.
For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.
Revision History Version:9.40.12.0 (19 Feb 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.30.15.0 (26 Oct 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Logical Drive Movement enhancements
Version:9.20.9.0 (4 Sep 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Smart Array P721m
Version:9.10.22.0 (4 Jun 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.10.22.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.
Version:9.0.24.0 (27 Mar 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 9.0.24.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
These versions of the utilities support:
The following controllers:
HP Smart Array P222
HP Smart Array P420
HP Smart Array P421
HP Smart Array P220i
HP Smart Array P420i
Added support for the following features/devices:
Smart Array Advanced Pack 2.0 (SAAP 2.0)
SAAP 2.0 provides full SAAP 1.0 feature functionality with the following additions:
RAID 1/10 Advanced Data Mirroring (ADM)
Moving and Deleting of Individual Logical Volumes
Move operation now supports SATA to SAS, SAS to SATA
Predictive Spare Activation
128 physical drives
SmartSSD Wear Gauge
Updated Cache Ratio settings
Additional Strip Sizes - 512, 1024 on supported controllers and configurations
Device Temperatures - Controllers, Capacitors, Cache Modules, and Hard Drives
Overall Performance improvements
3 TB physical drives
Version:8.75.12.0 (22 Jun 2011)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
This offline environment includes 8.75.12.0 versions of:
Array Configuration Utility (HP ACU)
Array Configuration Utility CLI (HP ACUCLI)
Array Configuration Scripting (HP ACU Scripting)
The Array Diagnostics and SmartSSD Wear Gauge features are embedded in the ACU and HP ACUCLI utilities themselves
The 8.75.12.0 versions of the utilities support:
SmartSSD Wear Gauge
This feature is accessible through the Diagnostic Tab in ACU, and the ssdinfo command in ACUCLI
Greater than 2.2 TB Hard Drives
Hp Smart Array Configuration Utility Download
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models. Printable version HP ProLiant Array Configuration Utility for Windows 64-bit
By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: Software - System Management Version: 9.40.12.0(19 Feb 2013) Operating System(s): Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 x64 Microsoft Windows Server 2012 Microsoft Windows Storage Server 2003 x64 Editions Microsoft Windows Unified Data Storage Server 2003 x64 Edition Microsoft Windows Vista (64-bit) Microsoft Windows XP Professional x64 Edition Microsoft Windows 7 (64-bit) File name: cp018121.exe (6.0 MB) The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, or to reconfigure your array controller.
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: cp018121.exe 655003c29b4cfcfc29c376aa8d77c6c5
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.
From that drive and directory, execute the downloaded file.
Click the 'Install' button to proceed with the installation. The utility will automatically be installed.
End User License Agreements:
Hewlett-Packard End User License Agreement
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.
For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.
The legacy ACU (native win32 application) and ACU executables can not be run on the same server at the same time; however, configurations created with one utility should be compatible with those created by the other.
Users will automatically be logged out after a predetermined period of inactivity when using ACU and will have to re-login.
On the Web-based Management Device Homepage, under 'options', 'Anonymous Access' should be enabled when using ACU.
When clicking on a controller that is currently being configured in a different ACU session, a message will appear which allows you to override the other ACU session or cancel. If you choose to override the other ACU session, any unsaved changes in the other session will be discarded.
To uninstall ACU, use Add/Remove Programs located in the Control Panel on Windows Systems.
To run ACU in local application mode on Windows, Internet Explorer must be the default browser.
The following are known issues:
Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.
When using Linux as the host operating system, if a Smart Array controller has 16 or more volumes configured, deleting any volume in the ACU will not update the /proc/partitions to reflect the deletion of the device node associated with that volume. Rebooting the server will cause the update to happen. Note that there is also a limitation that only the first 16 volumes configured will be available to the operating system. Version:9.40.12.0(B) (3 May 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Install this 9.40.12.0 (B) version if you require Windows Server 2008 R2. If you have successfully installed 9.40.12.0, then there is no need to install 9.40.12.0 (B).
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.40.12.0 (19 Feb 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.30.15.0 (26 Oct 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Logical Drive Movement enhancements
Version:9.20.9.0 (4 Sep 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Smart Array P721m
Version:9.10.22.0 (4 Jun 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the following controllers: Digno phone unlock code.
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added support for Simplified Chinese
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.
Type: Software - System Management Version: 9.40.12.0(19 Feb 2013) Operating System(s): Microsoft Windows 7 (64-bit) Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 x64 Microsoft Windows Server 2012 Microsoft Windows Storage Server 2003 x64 Editions Microsoft Windows Unified Data Storage Server 2003 x64 Edition Microsoft Windows Vista (64-bit) Microsoft Windows XP Professional x64 Edition Description The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, or to reconfigure your array controller. Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Installation Instructions
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: cp018121.exe 655003c29b4cfcfc29c376aa8d77c6c5
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.
From that drive and directory, execute the downloaded file.
Click the 'Install' button to proceed with the installation. The utility will automatically be installed. Release Notes
End User License Agreements:
Hewlett-Packard End User License Agreement
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.
For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.
The legacy ACU (native win32 application) and ACU executables can not be run on the same server at the same time; however, configurations created with one utility should be compatible with those created by the other.
Users will automatically be logged out after a predetermined period of inactivity when using ACU and will have to re-login.
On the Web-based Management Device Homepage, under 'options', 'Anonymous Access' should be enabled when using ACU.
When clicking on a controller that is currently being configured in a different ACU session, a message will appear which allows you to override the other ACU session or cancel. If you choose to override the other ACU session, any unsaved changes in the other session will be discarded.
To uninstall ACU, use Add/Remove Programs located in the Control Panel on Windows Systems.
To run ACU in local application mode on Windows, Internet Explorer must be the default browser.
The following are known issues:
Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.
When using Linux as the host operating system, if a Smart Array controller has 16 or more volumes configured, deleting any volume in the ACU will not update the /proc/partitions to reflect the deletion of the device node associated with that volume. Rebooting the server will cause the update to happen. Note that there is also a limitation that only the first 16 volumes configured will be available to the operating system. Revision History Version:9.40.12.0(B) (3 May 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Install this 9.40.12.0 (B) version if you require Windows Server 2008 R2. If you have successfully installed 9.40.12.0, then there is no need to install 9.40.12.0 (B).
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.40.12.0 (19 Feb 2013)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.30.15.0 (26 Oct 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Logical Drive Movement enhancements
Version:9.20.9.0 (4 Sep 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
End users may order paper copies of service, maintenance and workshop manuals for all Perkins engines from their local distributor. Distributors may obtain printed copies from our online site. How do I view my parts books? Parts books are available to view via the free Perkins My Engine App. Click here to download the app. Perkins 1000 Series PDF Service Manual.pdf: 3.3Mb: Download: Perkins 1000 Series New (Models AJ to AS and YG to YK) Workshop Manual.pdf: 18Mb: Download: Perkins 1100 Series 4 cylinder diesel engines workshop manual.pdf: 13.5Mb: Download: Perkins 1103 & 1104 Series Workshop Manual.pdf: 2.6Mb: Download: Perkins 1103 and 1104 Industrial Engine. Perkins engine service manual are used to repair a wide range of machinery, including Perkins tractor manual, Perkins generator manual and industrial tools and machinery. While the Perkins PDF manual download has customers in many sectors, the main consumer of their engines are used in Caterpillar, who are also the parent company. Perkins 2506c series generator service manual . Download 218 Perkins Engine PDF manuals. User manuals, Perkins Engine Operating guides and Service manuals.
Support for Smart Array P721m
Version:9.10.22.0 (4 Jun 2012)
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the following controllers:
HP Dynamic Smart Array B120i
HP Dynamic Smart Array B320i
HP Smart Array P822
Added support for Simplified Chinese
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
Replace Array
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
Heal Array
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
Spilt Mirror BackupRollback
Create Split Mirror Backup
This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
The backup array always contains RAID 0 logical drives.
The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
Manage Split Mirror Backup
This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
Activate the backup array. This option makes the backup array fully accessible to the operating system.
Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.
broken image